Curtainwall Parapet Stud Selector
Choose Stud Designation
250S137-33 33 KSI
250S137-43 33 KSI
250S137-54 50 KSI
250S137-68 50 KSI
250S162-33 33 KSI
250S162-43 33 KSI
250S162-54 50 KSI
250S162-68 50 KSI
350S162-33 33 KSI
350S162-43 33 KSI
350S162-54 50 KSI
350S162-68 50 KSI
362S137-33 33 KSI
362S137-43 33 KSI
362S137-54 50 KSI
362S137-68 50 KSI
362S162-33 33 KSI
362S162-43 33 KSI
362S162-54 50 KSI
362S162-68 50 KSI
362S200-33 33 KSI
362S200-43 33 KSI
362S200-54 50 KSI
362S200-68 50 KSI
400S137-33 33 KSI
400S137-43 33 KSI
400S137-54 50 KSI
400S137-68 50 KSI
400S162-33 33 KSI
400S162-43 33 KSI
400S162-54 50 KSI
400S162-68 50 KSI
400S200-33 33 KSI
400S200-43 33 KSI
400S200-54 50 KSI
400S200-68 50 KSI
550S162-33 33 KSI
550S162-43 33 KSI
550S162-54 50 KSI
550S162-68 50 KSI
600S162-33 33 KSI
600S162-43 33 KSI
600S162-54 50 KSI
600S162-68 50 KSI
600S162-97 50 KSI
600S200-33 33 KSI
600S200-43 33 KSI
600S200-54 50 KSI
600S200-68 50 KSI
600S200-97 50 KSI
600S250-43 33 KSI
600S250-54 50 KSI
600S250-68 50 KSI
600S250-97 50 KSI
800S162-33 33 KSI
800S162-43 33 KSI
800S162-54 50 KSI
800S162-68 50 KSI
800S162-97 50 KSI
800S200-33 33 KSI
800S200-43 33 KSI
800S200-54 50 KSI
800S200-68 50 KSI
800S200-97 50 KSI
800S250-43 33 KSI
800S250-54 50 KSI
800S250-68 50 KSI
800S250-97 50 KSI
1000S162-43 33 KSI
1000S162-54 50 KSI
1000S162-68 50 KSI
1000S162-97 50 KSI
1000S200-43 33 KSI
1000S200-54 50 KSI
1000S200-68 50 KSI
1000S200-97 50 KSI
1000S250-43 33 KSI
1000S250-54 50 KSI
1000S250-68 50 KSI
1000S250-97 50 KSI
1200S162-54 50 KSI
1200S162-68 50 KSI
1200S162-97 50 KSI
1200S200-54 50 KSI
1200S200-68 50 KSI
1200S200-97 50 KSI
1200S250-54 50 KSI
1200S250-68 50 KSI
1200S250-97 50 KSI
(Nomenclature as per SSMA standard. SSMA is Steel Stud Manufacturer's Association.)
Specify Distance - Floor to Attachment
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Feet
0
1
2
3
4
5
6
7
8
9
10
11
Inches
(Elevation of attachment point. The attachment is assumed to be a pinned connection.)
Specify Distance - Attachment to Parapet Top
1
2
3
4
5
6
7
8
9
10
Feet
0
1
2
3
4
5
6
7
8
9
10
11
Inches
Choose Backside Suction Pressure
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
psf
(Typically, this would be the "Components & Cladding" pressure for Leeward Side Area 5 w/ negative GCpi.)
Choose Parapet Positive Pressure
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
psf
(Typically, this would be the "Components & Cladding" pressure for Windward Side w/ positive GCpi at an appropriate elevation.)
Choose Stud Spacing
6
8
12
16
24
Inches
Choose Deflection Criteria
L/120
L/240
L/360
L/600
L/720
(L/240 is recommended for EIFS or metal facade. L/600 for brick facade. L/720 for stone facade.)
Use 70% of Component And Cladding Pressure for Curtainwall Deflection, per AISI S211-07 A3.1 (c)?
Consider Distortional Buckling?
(Results will be displayed on the next web page titled "Curtainwall Parapet Stud Selector - Calculated Results".)
Important Note: This analysis tool is intended to serve as a general guide to architects and contractors for estimating requirements for curtainwall studs configured as parapets. This tool must NOT be used for construction, final design and/or selection of such parapet curtainwall studs without an independant evaluation by a qualified cold-formed steel design engineer. There are other factors, other than those listed above, which may impact upon the design/selection process of curtainwall studs configured as parapets, which are NOT addressed by this tool. K2 Engineering, Inc. and it's employees and associates, specifically disclaim any responsibility and/or liability for failure, or any other sort of consequential damages, resulting from the misuse or mis-application of this tool and its results. K2 Engineering, Inc. makes no warranties, expressed or implied, regarding this tool. The User of this tool proceeds at his/her own risk.